HIDIC-S10/2α/mini CPU equivalent to attached port

<< Click to Display Table of Contents >>

Manuals > Device Connection Guide > Hitachi > Connection Procedure (RS-232C) >

HIDIC-S10/2α/mini CPU equivalent to attached port

About the connection example

Please see below for an example of connection settings for this driver.

 

Applicable models etc.

explanation

Connection example [HIDIC-2aH series]

This is an example of connection settings via RS-232C with the HIDIC-2aH series.

 

 

 

Device List

The compatible devices are as follows (see here for how to view the device list).

 

device

keyword

Start address

explanation

unit

reading

Writing

Address specification (16-bit units)

AW

060000

Hexadecimal

word

○

●

Address specification (32-bit units)

AD

060000

Hexadecimal

Double Word

○

●

External Input

X

000

Hexadecimal

bit

○

○

Transfer Register

J

000

Hexadecimal

bit

○

○

External Output

Y

000

Hexadecimal

bit

○

○

Receive Register

Q

000

Hexadecimal

bit

○

○

Global Link Register

G

000

Hexadecimal

bit

○

○

Internal Registers

R

000

Hexadecimal

bit

○

○

Extended Internal Registers

M

000

Hexadecimal

bit

○

○

Keep Relay

K

000

Hexadecimal

bit

○

○

On-delay timer (contact)

TK

000

Hexadecimal

bit

○

○

On-delay timer (coil)

T

000

Hexadecimal

bit

○

○

One-shot timer (contact)

UK

000

Hexadecimal

bit

○

○

One-shot timer (coil)

U

000

Hexadecimal

bit

○

○

Counter (up coil)

CU

00

Hexadecimal

bit

○

○

Counter (down coil)

CD

00

Hexadecimal

bit

○

○

Counter (contact)

C

000

Hexadecimal

bit

○

○

Counter (reset coil)

CR

00

Hexadecimal

bit

○

○

Nesting coil (contact)

N

000

Hexadecimal

bit

○

○

Process Coil

P

000

Hexadecimal

bit

○

○

Edge Contacts

V

000

Hexadecimal

bit

○

○

Event Register

E

000

Hexadecimal

bit

○

○

Z Register

Z

000

Hexadecimal

bit

○

○

System Registers

S

000

Hexadecimal

bit

○

○

External Input

XW

000

Hexadecimal

word

○

●

Transfer Register

JW

000

Hexadecimal

word

○

●

External Output

YW

000

Hexadecimal

word

○

●

Receive Register

QW

000

Hexadecimal

word

○

●

Global Link Register

GW

000

Hexadecimal

word

○

●

Internal Registers

RW

000

Hexadecimal

word

○

●

Extended Internal Registers

MW

000

Hexadecimal

word

○

●

Keep Relay

KW

000

Hexadecimal

word

○

●

On-delay timer

TW

000

Hexadecimal

word

○

●

One Shot Timer

UW

000

Hexadecimal

word

○

●

Up/down counter

CW

000

Hexadecimal

word

○

●

Nesting coil

NW

000

Hexadecimal

word

○

●

Process Coil

PW

000

Hexadecimal

word

○

●

Edge Contacts

VW

000

Hexadecimal

word

○

●

Event Register

EW

000

Hexadecimal

word

○

●

Z Coil

ZW

000

Hexadecimal

word

○

●

System Registers

SW

000

Hexadecimal

word

○

●

Work Register

FW

000

Hexadecimal

word

○

●

Long word register (32 bits)

BD

000

Hexadecimal

Double Word

○

●

Extended external input

IW

000

Hexadecimal

word

○

●

Extended external output

OW

000

Hexadecimal

word

○

●

Data Register

DW

000

Hexadecimal

word

○

●

On-delay timer (setting value)

TS

000

Hexadecimal

word

○

●

One-shot timer (setting value)

US

000

Hexadecimal

word

○

●

Counter (setting value)

CS

000

Hexadecimal

word

○

●

On-delay timer (count value)

TC

000

Hexadecimal

word

○

●

One-shot timer (count value)

UC

000

Hexadecimal

word

○

●

Counter (count value)

CC

000

Hexadecimal

word

○

●

External input (32bit)

XL

000

Hexadecimal

Double Word

○

●

External output (32bit)

YL

000

Hexadecimal

Double Word

○

●

Internal register (32bit)

RL

000

Hexadecimal

Double Word

○

●

Extended internal register (32bit)

ML

000

Hexadecimal

Double Word

○

●

Data register (32bit)

DL

000

Hexadecimal

Double Word

○

●

Work register (32bit)

FL

000

Hexadecimal

Double Word

○

●

Extended external input (32bit)

IL

000

Hexadecimal

Double Word

○

●

Extended external output (32bit)

OL

000

Hexadecimal

Double Word

○

●

 

When specifying an address, please take note of the following:

 

Use "AW" when accessing in word units with absolute addressing. Specify the address as an even number (multiple of 2).

 

example)

Address AW061000 → DW000

Address AW061002 → DW001

Address AW061004 → DW002

 

Use "AD" when accessing in double-word units with absolute addressing.

 

Please specify the address in multiples of 4.

 

example)

Address AD061000 → DW000 to DW001 are interpreted as long words

Address AD061004 → DW002-DW003 are interpreted as long words

Address AD061008 → DW004 to DW005 are interpreted as long words

 

Long word devices (such as "XL", "YL", and "RL") are not defined in the PLC itself, but are virtually defined for the purpose of handling devices in long word units.

These are equivalent to "BW", "XW" and "YW" respectively, but handle values in 32-bit units. Addresses are specified as even numbers (multiples of 2).

 

Absolute addressing does not allow access to addresses earlier than 060000.

We cannot guarantee the operation of the PLC if accessed.

 

For devices that require addresses to be specified in multiples of 2 or 4, do not specify any other addresses.