QnA series equivalent to AJ71QC24

<< Click to Display Table of Contents >>

Manuals > Device Connection Guide > Mitsubishi Electric > Open Protocol (RS-232C) >

QnA series equivalent to AJ71QC24

About the connection example

Please see below for an example of connection settings for this driver.

 

Applicable models etc.

explanation

Connection example [QnA series]

This is an example of connection settings with the QnA series via RS-232C.

 

 

 

Device List

The compatible devices are as follows (see here for how to view the device list).

 

device

keyword

Start address

explanation

unit

reading

Writing

Input Relay

X

000000

Hexadecimal

bit

○

○

Output Relay

Y

000000

Hexadecimal

bit

○

○

Internal Relay

M

000000

Decimal

bit

○

○

Special Relay

SM

000000

Decimal

bit

○

○

Latching Relay

L

000000

Decimal

bit

○

○

Annunciator

F

000000

Decimal

bit

○

○

Edge Relay

V

000000

Hexadecimal

bit

○

○

Link Relay

B

000000

Hexadecimal

bit

○

○

Special Link Relay

SB

000000

Decimal

bit

○

○

Step Relay

S

000000

Decimal

bit

○

○

Timer Contact

TS

000000

Decimal

bit

○

○

Timer coil

TC

000000

Decimal

bit

○

○

Integration Timer Contact

SS

000000

Decimal

bit

○

○

Accumulator timer coil

SC

000000

Decimal

bit

○

○

Counter Contact

CS

000000

Decimal

bit

○

○

Counter coil

CC

000000

Decimal

bit

○

○

Timer current value

TN

000000

Decimal

word

○

●

Current value of the integration timer

SN

000000

Decimal

word

○

●

Counter current value

CN

000000

Decimal

word

○

●

Data Register

D

000000

Decimal

word

○

●

Special Registers

SD

000000

Decimal

word

○

●

Link Register

W

000000

Hexadecimal

word

○

●

Special Link Register

SW

000000

Hexadecimal

word

○

●

Index Register

Z

000000

Decimal

word

○

●

File Register

(Current block)

R

000000

Decimal

word

○

●

File Register

(Sequential number)

ZR

000000

Hexadecimal

word

○

●

File Register

(Sequential number)

ZZR

0000000

Decimal

word

○

●

 

attention

When specifying an address for a ZR (file register) in decimal notation, use "ZZR".

 

About the access station

There are two connection methods supported for connecting to the QnA Series CPU, depending on the network configuration. An access station is a connection station that connects to a personal computer via a connection station. When connecting to an access station, refer to the setting example below.

 


Access Station 1: When you want to communicate with a PLC connected to a PC

c_plc_0049

 

Select the driver for access station 1.

c_plc_0084

 


Access station 2: When you want to communicate with a PLC connected via a network from access station 1

c_plc_0051

Select the driver for access station 2.

c_plc_0085

 

Add a driver for access station 2, and in the unit's communication settings, set it to connect to access station 1. Then add a folder, and in the folder's communication settings, set the connection parameters to access station 2.

c_plc_0053   c_plc_0054