AnA/U Extended address equivalent to AJ71UC24

<< Click to Display Table of Contents >>

Manuals > Device Connection Guide > Mitsubishi Electric > Open Protocol (RS-232C) >

AnA/U Extended address equivalent to AJ71UC24

About the connection example

Please see below for an example of connection settings for this driver.

 

Applicable models etc.

explanation

Connection example [AnU series]

This is an example of connection settings via RS-232C with the AnU series.

 

 

 

About the A series driver

There are two types of A series drivers:

 

1.MELSEC-A CPU Normal address
It can be used with all CPUs in the A series, but the accessible addresses are more limited than those of "MELSEC-AnA/AnU".

 

2.MELSEC-AnA/AnU Extended Address
The models that can be used are limited to AnA and AnU, but the addresses are extended.

 

The accessible address range is specified in the Computer Link manual published by the manufacturer. For details, see "Device range when using ACPU common commands" (page 5-36) and "Device range when using AnA/AnUCPU common commands" (page 5-39) in the Computer Link/Multidrop Link Unit User's Manual (manual type name "KEISANKI-U-KP").

 

 

Device List

The compatible devices are as follows (see here for how to view the device list).

 

A series normal address

device

keyword

Start address

explanation

unit

reading

Writing

Input Relay

X

0000

Hexadecimal

bit

○

○

Output Relay

Y

0000

Hexadecimal

bit

○

○

Internal Relay

M

0000

Decimal

bit

○

○

Special Relay

M

9000

Decimal

bit

○

○

Latching Relay

L

0000

Decimal

bit

○

○

Step Relay

S

0000

Decimal

bit

○

○

Link Relay

B

0000

Hexadecimal

bit

○

○

Annunciator

F

0000

Decimal

bit

○

○

Timer Contact

TS

000

Decimal

bit

○

○

Timer coil

TC

000

Decimal

bit

○

○

Counter Contact

CS

000

Decimal

bit

○

○

Counter coil

CC

000

Decimal

bit

○

○

Timer current value

TN

000

Decimal

word

○

●

Counter current value

CN

000

Decimal

word

○

●

Data Register

D

0000

Decimal

word

○

●

Special Registers

D

9000

Decimal

word

○

●

Link Register

W

0000

Hexadecimal

word

○

●

File Register

R

0000

Decimal

word

○

●

Extended File Register (Block)

R

0000000

Decimal number 3 digits (block number) + 4 digits (0 to 8191)

word

○

●

 

AnA/U Address extension

device

keyword

Start address

explanation

unit

reading

Writing

Input Relay

X

000000

Hexadecimal

bit

○

○

Output Relay

Y

000000

Hexadecimal

bit

○

○

Internal Relay

M

000000

Decimal

bit

○

○

Special Relay

M

009000

Decimal

bit

○

○

Latching Relay

L

000000

Decimal

bit

○

○

Step Relay

S

000000

Decimal

bit

○

○

Link Relay

B

000000

Hexadecimal

bit

○

○

Annunciator

F

000000

Decimal

bit

○

○

Timer Contact

TS

00000

Decimal

bit

○

○

Timer coil

TC

00000

Decimal

bit

○

○

Counter Contact

CS

00000

Decimal

bit

○

○

Counter coil

CC

00000

Decimal

bit

○

○

Timer current value

TN

00000

Decimal

word

○

●

Counter current value

CN

00000

Decimal

word

○

●

Data Register

D

000000

Decimal

word

○

●

Special Registers

D

009000

Decimal

word

○

●

Link Register

W

000000

Hexadecimal

word

○

●

File Register

R

000000

Decimal

word

○

●

Extended File Register (Block)

R

0000000

Decimal number 3 digits (block number) + 4 digits (0 to 8191)

word

○

●

Extended file register (sequential number)

R

0000000

 

word

○

●