This event occurs each time a refresh communication for automatic updates is completed.
syntax
Private Sub AxEng1_ValueRefresh(sender As Object,
e As AxFAENGINELib6._DFAEngineEvents_ValueRefreshEvent)
Handles AxEng1.ValueRefresh
Parameters
e.folderPath
|
|
type:
|
string
|
|
Folder path. Example: U01.F01
|
e.result
|
|
type:
|
bool
|
|
FALSE - Failure. TRUE - Success.
|
Commentary
This event occurs each time communication for automatic updates is completed. Within this event, the updated value can be obtained quickly using the GetVal method. Since automatic updates are performed at regular intervals, this event can be used in situations where you want to log data periodically. It also occurs after the ReadRefresh method is called.
|
reference
|