FireAlarm

<< Click to Display Table of Contents >>

Manual > Control Reference > Route > Route Methods >

FireAlarm


 

Invokes the specified Alarm server action or the default FireAlarm.

 


Syntax 1

FireAlarm(

         alarmAction,

         alarmID,

         conditionID

         [,commentID]

         [,comment]

         )

 


Parameters

 

alarmAction


Type:

character


Alarm serverAction name. If #NOTHING# or an empty string is specified, the action name specified in the DefaultFireAlarm route property will be used.

 

alarmID


Type:

character


Alarm ID. If #NOTHING# or an empty string is specified, the AlarmID specified in the DefaultFireAlarm route property will be used.

 

conditionID


Type:

Number


Condition ID.

When multiple [ONCONDITION] are specified in the alarm master, specify the numbers from top to bottom starting with 0. If there is one alarm condition, specify 1 (if there is an occurrence and return, occurrence is 1 and return is 0). If #NOTHING# is specified, the ConditionID specified in the DefaultFireAlarm root property will be used.

 

commentID


Type:

Number


Comment ID. Array can be specified. If comment columns such as [CM0], [CM1] are specified in the alarm master, specify the comment number. If #NOTHING# is specified, the CommentID specified in the DefaultFireAlarm root property will be used.

 

comment


Type:

character


Comment. Array can be specified. Specify the actual comment for the comment column specified by commentID.

 

Return Value



Type:

Boolean


FALSE - Failure. TRUE - Success.

 


Syntax 2

FireAlarm(

         comment

         )

 


Parameters

 

comment


Type:

character


Comment. Array can be specified. Specify the actual comment for the comment column specified by commentID.

 

Return Value



Type:

Boolean


FALSE - Failure. TRUE - Success.

 

 


hmtoggle_plus1Explanation

 


Supported


×

Script Action

○

Browser script

×

Calculation Expression Syntax

 