KV-700 KV-LE20

<< Click to Display Table of Contents >>

Manual > Device Connection Guide > Keyence > Connection Procedure (Ethernet) >

KV-700 KV-LE20

About the connection example

Please see below for an example of connection settings for this driver.

 

Applicable models etc.

explanation

Connection example [KV-700]

This is an example of connection settings with the Keyence KV-700 series.

 

 

*For connection settings with other compatible models, please refer to the above.

 

 

Device List

The compatible devices are as follows (see here for how to view the device list).

 

device

keyword

Start address

explanation

unit

reading

Writing

Input/Output/Auxiliary Relays

R

00000

Decimal number 3 digits + 2 digits (00 to 15)

bit

Control Relay

CR

0000

Decimal number 2 digits + 2 digits (00 to 15)

bit

Timer Contact

T

000

Decimal

bit

Counter Contact

C

000

Decimal

bit

High-speed counter contact

CTH

0

Decimal

bit

High-speed counter comparator contact

CTC

0

Decimal

bit

Timer setting value

TS

000

Decimal

word

Counter setting value

CS

000

Decimal

word

High-speed counter setting value

CTHS

0

Decimal

word

High-speed counter comparator setting value

CTCS

0

Decimal

word

Timer current value

TN

000

Decimal

word

Counter current value

CN

000

Decimal

word

High-speed counter current value

CTHN

0

Decimal

word

High-speed counter comparator current value

CTCN

0

Decimal

word

Temporary Data Memory

TM

000

Decimal

word

Control Memory

CM

00000

Decimal

word

Data Memory

DM

00000

Decimal

word