KZ-300/350 KZ-L2

<< Click to Display Table of Contents >>

Manual > Device Connection Guide > Keyence > Connection Procedure (RS-232C) >

KZ-300/350 KZ-L2

About the connection example

Please see below for an example of connection settings for this driver.

 

Applicable models etc.

explanation

Connection example [KZ-300]

This is an example of connection settings with the Keyence KZ-300 series.

 

 

*For connection settings with other compatible models, please refer to the above.

 

 

Device List

The compatible devices are as follows (see here for how to view the device list).

 

device

keyword

Start address

explanation

unit

reading

Writing

Input/Output/Auxiliary Relays

R

000000

4 decimal digits + 2 hexadecimal digits

bit

Temporary Data Memory

TM

0000

Decimal

word

Analog Timer Trimmer Value

TMIN

0000

Decimal

word

Timer/Counter Contact

TC

0000

Decimal

bit

High Speed Counter Comparator

CTC

0000

Decimal

bit

Timer setting value

TS

0000

Decimal

word

Counter setting value

CS

0000

Decimal

word

High-speed counter setting value

CTCS

0000

Decimal

word

Timer/Counter Current Value

TCN

0000

Decimal

word

High-speed counter current value

CTH

0000

Decimal

word

Data Memory

DM

0000

Decimal

word

Input/Output/Auxiliary Relays

IO

000000

4 decimal digits + 2 hexadecimal digits

bit

 

hint

IO and R both mean "Input/Output/Auxiliary Relay".

IO is provided for compatibility with previous versions, but R should be used officially.