Analog Meter 2

<< Click to Display Table of Contents >>

Manual > Library Reference > Parts Library > Basic Parts >

Analog Meter 2

Analog Meter 2

 

parts_analogmeter2_001

Analog Meter 2 is a component that displays the value received from the tag with a meter needle.

In addition to the meter needle display, it also has a numerical display.

 

Specify the tag to be displayed in the input tag (_TagIn). You can specify any numeric format, such as the number of decimal places, whether to display delimiters, etc.

You can also display zones on the meter for any range you like. For example, you can display safe and dangerous ranges of measurement values as strips.

 

In addition to the input tag, by specifying a tag for fault identification in the fault identification tag (_TagFault), it is also possible to display a fault based on signals such as equipment abnormalities received from downstream.

 

 

Custom Properties

 

Tag configuration

Input Tags

_TagIn

Specify the tag path of the input tag.


Fault Identification Tag

_TagFault

Specifies the tag path of the fault identification tag.

Display settings

Number Format

_Format

Specifies the number format.


Decimal point position

_DecimalPlace

Specify the number of decimal points as an integer.


caption

_Caption

Specify a caption.


unit

_Unit

Specify the units.


Minimum

_Min

Specifies the minimum value, which is used as the meter's display width.


Maximum

_Max

Specifies the maximum value, which is used as the meter's display width.


Caption Color

_CaptionColor

Specifies the color of the caption.


Unit Color

_UnitColor

Specifies the color of the units.


Value Text Color

_ValueTextColor

Specifies the color of the value text.


Value Background Color

_ValueFillColor

Specifies the background color of the value.

Meter Display

Needle Color

_NeedleColor

Specifies the color of the meter needle.


Panel Color 1

_PanelColor

Specifies the meter panel color.


Panel Color 2

_FrameColor

Specifies the meter panel color (outer frame).


Background Panel

_ShowBackPanel

Specifies whether to show or hide the background panel.


Background Panel Color

_BackPanelColor

Specifies the color of the background panel.


Gauge Color

_GaugeLineColor

Specifies the gauge line color.


Text Color

_GaugeTextColor

Specifies the gauge (scale) text color.


Corner radius

_BackPanelRound

Specifies the radius of the corners of the background panel. Specify the diameter of the circle in pixels.

Zone Display

Zone Display

_ShowZoneLine

Specifies whether to show or hide the zone display.


Display Color

_ZoneLineColor

Specifies the display color of the zone.


Minimum

_ZoneLineMin

Specifies the minimum value (start position) of the zone display.


Maximum

_ZoneLineMax

Specifies the maximum value (end position) of the zone display.


Display Width

_ZoneLineWidth

Specifies the display width of the zone band in pixels.

others

Display value

_Value

You can directly assign a display value to this property from a script.

 

Usage Example

 

1) Input tag specified/No fault identification tag

 

Displays the value of the tag specified in the input tag.

 

parts_analogmeter2_001

The number is displayed according to the number format and decimal places defined in the custom properties.

 

If the quality flag of the input tag is BAD, a fault is displayed.
 

parts_analogmeter2_002

The part will be framed in yellow and will flash.

 

 

hint

There are various number formats available (e.g. "@de" for Germany, "@ja" for Japan, etc.). The number format can also be customized. For example, you can freely specify the string to be displayed in a fault state (e.g. ***). For details about number formats, see Number Formats.

 

 

2) Input tag specified/Fault identification tag

 

If you specify a fault identification tag, you can receive the fault status of the device via the tag. For example, if you can receive a fault status (such as a sensor abnormality) from the downstream side as a signal separate from the device's measurement value, you can specify the tag path of that signal as the fault identification tag to display the fault along with the state of the quality flag of the input tag.

 

parts_analogmeter2_001

When the fault identification tag is False, the value received in the input tag is displayed normally.

 

 

parts_analogmeter2_002

A fault is displayed when the fault identification tag is true or when the quality flag of the input tag is bad.

 

 

3) Assigning values via script

 

You can display any numeric value entered from the script without specifying an input tag.

If you want to assign a value directly from a script, do so to the "_Value" property.

 

hint

If you assign a value directly from a script, you cannot use a fault identification tag.

For more information about scripts, see "Scripts".

 

 

 

4) Change the number format

 

You can change the number format to display numbers in various formats.

 

parts_analogmeter2_003

In this example, the number format is specified as "@de" (Germany).

The same format is reflected in both the numeric display and the gauge display.

 

*In German format, the decimal point is displayed as a comma instead of a period.