OnAlarmNotificationDone

<< Click to Display Table of Contents >>

Manual > Control Reference > Data > Remote alarm grid client control > Events >

OnAlarmNotificationDone


 

Occurs when the alarm notification is finished.

 


syntax

event OnAlarmNotificationDone (

         bComplete,

         showRecordCnt,

         searchRecordCnt,

         actualShowRecordCnt,

         actualSearchRecordCnt,

         lastRecordDate

         )

 


Parameters

 

bComplete


Type:

Boolean


TRUE - All alarms have been notified.

FALSE - There are pending alarms.

The following cases will result in FALSE.

1) The search for the record specified by SearchRecordCnt has been completed, so there may still be remaining records.

2) The number of records specified by ShowRecordCnt has been displayed, but there may still be remaining records.

 

showRecordCnt


Type:

Number


The value of ShowRecordCnt specified when calling SubscribeHistorical.

 

searchRecordCnt


Type:

Number


The value of SearchRecordCnt specified when calling SubscribeHistorical.

 

actualShowRecordCnt


Type:

Number


The number of records actually displayed.

 

actualSearchRecordCnt


Type:

Number


The actual number of records found.

 

lastRecordDate


Type:

character


The date and time of the last record.

 