<< Click to Display Table of Contents >> Manual > Library Reference > Parts Library > Basic Parts > Numeric Input 1 |
Numeric Input 1
|
Numeric Input 1 is a component for writing the numerical value entered on the screen to a tag. When the edit is confirmed, the value is written to the input/output tag.
|
Specify the tag to be input/output as the input/output tag (_TagInOut). The value of the input/output tag will be the initial display, and thereafter the display will be dynamically updated every time the value changes.
When editing a value, only values within the range specified by the minimum and maximum values will be accepted. Once the edit is confirmed, the value will be written to the input/output tag. The displayed value will be the tag's numeric value regardless of the minimum and maximum settings, and any numeric format can be specified, including the number of decimal places and whether or not to display delimiters.
In addition, by specifying a tag for fault identification in the fault identification tag (_TagFault) separate from the input tag, a fault can be displayed based on signals such as equipment abnormalities received from downstream.
Custom Properties
Tag configuration |
Input/Output Tags |
_TagInOut |
Specifies the tag path of the input/output tag. |
Fault Identification Tag |
_TagFault |
Specifies the tag path of the fault identification tag. |
|
Display settings |
Number Format |
_Format |
Specifies the number format. |
Decimal point position |
_DecimalPlace |
Specify the number of decimal points as an integer. |
|
caption |
_Caption |
Specify a caption. |
|
unit |
_Unit |
Specify the units. |
|
Minimum |
_Min |
Specifies the minimum value. |
|
Maximum |
_Max |
Specifies the maximum value. |
|
Value Text Color |
_ValueTextColor |
Specifies the color of the value text. |
|
Value Background Color |
_ValueFillColor |
Specifies the background color of the value. |
|
Caption Color |
_CaptionColor |
Specifies the color of the caption. |
|
Unit Color |
_UnitColor |
Specifies the color of the units. |
|
Background Panel |
_BackPanelColor |
Specifies the color of the background panel. |
|
Input assistance settings |
cursor |
_StartCursor |
Specifies the initial cursor state when focused. •NONE - Do not select •MOUSE - Set cursor to mouse position •LEFT ・・・Sets the cursor to the left of the input value •RIGHT ・・・Set the right cursor of the input value •SELECTALL ・・・Select all the entered values |
Error Message |
_ErrorMsg |
Specifies the error message. |
|
Error display |
_ShowErrorMsg |
If you enable message display, an error message will pop up when an error occurs (e.g., an out-of-range number is entered). |
|
Keyboard display |
_ShowKeyboard |
If enabled, the keyboard dialog will be displayed on focus. |
|
Operation history output |
_Log |
If enabled, the operation history will be output when a value is written. If you want to output the operation history in a standard project that uses the standard framework, enable the operation history setting from the system administration settings screen. For details, see "Operation History Settings". If you want to output the operation history in an original project that does not use the standard framework, define Alarm server to record the operation history and set the root DefaultFireAlarm property appropriately. |
|
Operation Message |
_LogMsg |
Specify the message to be output to the operation history. |
Usage Example
1) Input/output tag specified/no fault identification tag
|
The value of the input/output tag is displayed according to the number format and decimal point position defined in the custom properties. When the tag value changes, the display updates dynamically.
|
|
When the item is focused by clicking the mouse, the value can be edited. In the example on the left, all items are selected using the cursor setting "SELECTALL". |
|
Enter a value from the keyboard. You can enter a value within the range set by the maximum and minimum values. Here, the input will be confirmed when you lose focus by pressing the Enter key or clicking on another object. |
|
The entered value is written to the I/O tag and displayed in the specified numeric format. |
When the quality flag of the input/output tag is BAD, a fault is displayed.
|
The part will be framed in yellow and will flash. When a fault is displayed, the input frame is disabled and editing is not possible. |
|
Various number formats are available (e.g. "@de" for Germany, "@ja" for Japan, etc.). You can also customize the number format to freely change the string displayed in a fault state (e.g. ***). For an overview of number formats, see Number Formats.
If you want to change the string displayed when the quality flag is BAD (QualityBad) as shown below, please refer to Number format (user format). Example: If you want to display a different string when the quality flag is BAD Example: When the quality flag is BAD, you want to display the final value when communication is successful.
|
|
By setting the "FocusHover" property of the form to which the component is attached to True, a focus frame will be displayed when you move the mouse cursor over the component you want to operate. |
2) Input/output tag specified/fault identification tag
If you specify a fault identification tag, you can receive the fault status of the device via the tag. For example, if you can receive a fault status (such as a sensor abnormality) from the downstream side as a signal separate from the device's measurement value, you can specify the tag path of that signal as the fault identification tag to display the fault along with the state of the quality flag of the input tag.
|
When the fault identification tag is False, the value received by the input/output tag is displayed and can be edited as usual.
|
|
A fault is displayed when the fault identification tag is true or when the quality flag of the input/output tag is bad. When a fault is displayed, the input frame is disabled and editing is not possible. |
3) Change the number format
You can change the number format to display numbers in various formats.
|
In this example, the number format is specified as "@de" (Germany). In the German format, the decimal point is displayed as a comma instead of a period, and the comma is also treated as a decimal point when editing.
|
4) Keyboard display
If you enable keyboard display (_ShowKeyboard), the keyboard dialog (numeric keypad) will be displayed when the focus is on the control.
|
You can edit the value using the numeric keypad on the dialog. Clicking the OK button closes the dialog, the edited result is reflected in the input box, and the value is written to the input/output tag.
|
5) Error message display
If you enable error display (_ShowErrorMsg), a message box will be displayed when an input error occurs.
|
The content to be displayed can be specified using the error message (_ErrorMsg).
|