<< Click to Display Table of Contents >> Manual > Device Connection Guide > Mitsubishi Electric > Private Protocol > General Explanation > Error Codes |
Private protocol error codes
Below are the error codes for private protocols.
Code (HEX) |
Contents |
Cause |
treatment |
01801005 |
Specified port error |
The specified port does not exist |
Specify the correct port |
01801006 |
Specified unit error |
The specified UNIT does not exist. |
Specify the correct unit |
01801007 |
Specified CPU error |
The specified CPU does not exist. |
Specify the correct CPU |
01801008 |
Access Error |
Access to the specified CPU is not permitted |
No access |
01802001 |
Device Error |
The specified device does not exist for the CPU type specified in Open. |
Specify the correct device |
01802002 |
Device number error |
The specified device is out of range |
Specify the correct device number |
01802004 |
Sum check error |
A communication result checksum error occurred. |
Retry or check communication line |
01802005 |
Overscore error |
The specified number of points is out of range. |
Specify the correct number of access points |
01802006 |
Block number error |
The specified block number does not exist. |
Specify the correct block number |
01802007 |
Received data error |
The received data is abnormal. |
Retry |
01802016 |
Station number setting error |
The specified area code does not exist. |
Specify the correct area code |
01802023 |
SFC Block No. Error |
The specified SFC block number does not exist. |
Specify the correct SFC block number. |
01802024 |
SFC Step No. Error |
The specified SFC step number does not exist. |
Specify the correct SFC step number. |
01808001 |
Double open error |
Opened in OPEN state |
|
01808002 |
Channel number specification error |
The channel number setting is invalid. |
Set the correct value |
01808003 |
Driver not started error |
The driver is not started |
Start the driver |
01808009 |
Error opening COMM |
Unable to open COMM port handle |
COMM Specify the correct port |
01808101 |
Double close error |
Close was executed without port being opened. |
|
01808201 |
Transmission Error |
Data transmission failed. |
|
01808301 |
Reception Error |
Data reception failed |
|
01808406 |
Baud rate specification error |
The baud rate setting is invalid. |
Set the correct value |
01808407 |
Data length specification error |
The data length setting is invalid. |
Set the correct value |
01808408 |
Parity specification error |
The parity setting is invalid. |
Set the correct value |
01808409 |
Stop bit specification error |
The stop bit setting is invalid. |
Set the correct value |
0180840A |
Communication control specification error |
The communication control setting is invalid. |
Set the correct value |
0180840B |
Timeout Error |
Data could not be sent or received within the specified time. |
Increase the timeout value |
0101001A |
Target Busy |
There were too many demands on the target CPU |
Consider scan time and link scan and try again |
01010020 |
Link Error |
A link error occurred |
Check for link-related errors (e.g., whether any stations are down) |
01010022 |
Time Over |
A timeout has occurred |
Try again When communicating via an intelligent special unit, increase the time check value. |
01024030 |
Inappropriate device |
The specified device name does not exist. |
Check the specified device name |
01024031 |
Device No. out of range |
The specified device number is out of range. |
Check the specified device number |
01024032 |
Inappropriate device |
An invalid device modifier was specified for the specified device. |
Check the specified device |
01024065 |
Device allocation error |
The device point setting specified in the parameter does not match the specified device point. |
Set the number of devices to the same as the number specified by the parameter |
01808411 |
TEL Password mismatch error |
||
10000022 |
The specified unit type is invalid. |
||
10000023 |
TEL communication error |